Industrial Electrical3 min read623 words
Smart Actuators Log Their Own Maintenance Data as Plants Cycle Harder
AUMA's PROFOX actuators log motor starts, run time and temperatures, and one offshore HVDC platform uses up to 800 of them. Nuclear replacement now demands full re-qualification of actuator, gearbox and valve as one system.

Clearance
- One offshore HVDC converter platform can use up to 800 AUMA actuators, mostly in the cooling system.
- AUMA's RSTX 100 remote operates actuators over Bluetooth at up to 20 meters and is certified intrinsically safe.
- PROFOX X is explosion-proof and certified for gas group IIC, which includes hydrogen.
- Nuclear qualification testing can include radiation, thermal aging, mechanical cycling, pressurization, vibration, and seismic loading.
- AUMA actuators log motor starts, run time, temperatures, and warning events for analysis in the CORALINK platform.
A single offshore HVDC converter platform can carry up to 800 electric actuators, mostly in the cooling system — and each one now logs its own condition data, from motor starts to run time to warning events, according to actuator maker AUMA.
That figure frames a shift underway in power plant valve and actuator practice. Equipment that electricians and plant techs have long treated as routine, well-maintained hardware is changing in three ways: digital diagnostics that move maintenance from reactive to planned, tighter accounting of lifetime energy and service costs, and, in nuclear plants, qualification and obsolescence demands that make actuator replacement far more than a mechanical swap.
Material from two manufacturers — AUMA and Rotork — details what that means on the plant floor, particularly as facilities cycle harder, take on hydrogen-capable duties, and run beyond their original design lives.
What Does the Actuator Record?
AUMA's PROFOX line of electric actuators comes in multi-turn, part-turn, and linear versions, covering the lower torque and thrust ranges. The company says variable-speed direct-current motors allow fast, precise positioning suited to closed-loop control, with speed profiles tunable to a specific process.
The bigger change is what the device logs. AUMA states the units record motor starts, run time, temperatures, and warning events, and that analyzing those logs can surface maintenance needs and process adjustments before an unplanned outage occurs.
Setup and diagnostics happen through a smartphone app or AUMA's RSTX 100 handheld remote. The remote works over Bluetooth at up to 20 meters, so technicians can operate an actuator in a pit or at height without climbing into a confined space. AUMA says the unit is certified intrinsically safe and can set end positions, update firmware, and pull log data for analysis in the company's CORALINK platform.
For hydrogen service, AUMA offers PROFOX X, an explosion-proof version certified for gas group IIC, which includes hydrogen.
Why Is Electric Actuation Winning on Cost?
AUMA also makes an operating-cost argument for electric over pneumatic actuation. Pneumatic actuators depend on a constant supply of compressed air, the company notes, while electric units draw significant power mainly while moving. Across a site with dozens or hundreds of actuators, that difference compounds.
Remote assets sharpen the math. Beyond the offshore wind example — up to 800 actuators on one HVDC converter platform — AUMA points to the cost of simply reaching equipment for maintenance at such sites, which makes any logged early warning worth more.
What Does Nuclear Qualification Require?
In nuclear plants, Rotork says actuators must deliver the force and speed required under emergency conditions without damaging valve stems, seats, or gear trains during normal operation. Sizing needs enough margin to overcome the highest expected valve loads, but too much output stresses mechanical components. Rotork says torque-limiting arrangements that work independently of the actuator's normal torque switches, plus thrust compensation that absorbs stem expansion from temperature changes, help strike that balance.
Safety-related actuators must also be qualified for their operating conditions. Rotork says testing can include radiation and thermal aging, mechanical cycling, pressurization, vibration, and seismic loading — with the goal of proving the actuator completes its safety function, not merely survives it.
What Does Replacement Involve at Aging Reactors?
As reactors run beyond their original design lives, Rotork argues, replacing an actuator means revisiting valve loads, operating times, power conditions, interfaces, and qualification criteria from scratch. Gearboxes may be needed to raise torque or convert output for quarter-turn valves, so the actuator, gearbox, and valve should be treated as one engineered system, not three separate purchases.
Whether the plant is a reactor or an offshore converter platform, the requirement stays the same: the valve must move when called upon.
via POWER Magazine (Source)
More from Amara Osei
Show full bio
Staff writer covering companies, deals and strategy in Wiring News is the daily trade press for at Wiring News.
10 articles
Alternates · Related articles
LS ELECTRIC Lands $93.83M Switchgear Order for US AI Data Center
LS Electric lands $93.83m switchgear order for hyperscale AI data center
LS Electric Lands $93.83M Switchgear Order for US AI Data Center Expansion
Moment Energy's Nova Puts Retired EV Packs to Work in 500 kWh Storage
LS Electric Lands $93.83M US Data Center Switchgear Order